FLUORESCENT PRODUCTS

Allanson’s Ferromagnetic High Output Fluorescent Ballasts are regarded as the most dependable ballasts in the industry, featuring reliable cold-weather operation, small housing size and lowest current draw. Available in Magnetic and Solid State variants. RSS Series Ballasts have become a favorite among service professionals because only three ballasts will service any HOF scenario, including long lamps. EESB Ballasts are designed for use with 800mA T12 HO, T8 HO ANSI standard, T8 Medium-Life, T8 Long-Life and Slim-Line lamps.

RSS Fluorescent Ballasts

  • Direct replacement for ferromagnetic ballasts (no rewiring required)
  • For use with T12 HO, T8 HO (2′ to 10′ in length)
  • 3 RSS Ballasts replace 15 existing models for less inventory requirements
  • Smaller profile allows for greater adaptability for low profile signage
  • Quite operation in all conditions. (Sound rated ‘A’)
  • Conventional series wiring
  • Cold weather start at -30C
  • Meets FCC rating, low RFI and EMI ensuring no interference
  • Meets ANSI C82.11 Standards
  • Less than 8% THD for installation confidence
  • Thermal protection
  • Increased lamp life

120 Volt Applications

For use with T12 HO and Slimline Lamps

SKU No. of Lamps Per Circuit Footage Combined Total Footage Input Voltage Max Input Amps Max Input Watts Open Circuit Voltage
RSS296AT 1-2 4′-16′ 4′-16′ 120V 1.60 190 950
RSS496AT 2-4 4′-16′ 8′-32′ 120V 3.20 370 950
RSS696AT 4-6 12′-24′ 24′-48′ 120V 4.15 490 950
RSS1648-26L 2-6 8′-24′ 16′-48′ 120V 3.85A 430 950

For use with T8 HO and Slimline Lamps

SKU No. of Lamps Per Circuit Footage Combined Total Footage Input Voltage Max Input Amps Max Input Watts Open Circuit Voltage
RSS296AT 1-2 4′-12′ 4′-16′ 120V 1.60 190 950
RSS496AT 2-4 4′-12′ 8′-24′ 120V 3.20 362 950
RSS696AT 4-6 9′-18′ 18′-36′ 120V 4.10 478 950
RSS1648-26L 2-6 8′-18′ 16′-36′ 120V 3.82 435 950

120-277 Volt Applications

For use with T12 HO and Slimline Lamps

SKU No. of Lamps Per Circuit Footage Combined Total Footage Input Voltage Max Input Amps Max Input Watts Open Circuit Voltage
RSS296AT-120-277V 1-2 4′-16′ 4′-16′ 120-277V 1.50-0.71 180-176 950
RSS496AT-120-277V 2-4 4′-16′ 8′-32′ 120-277V 3.00-1.42 360-352 950
RSS696AT-120-277V 4-6 12′-24′ 24′-48′ 120-277V 3.85-188 460-456 950

For use with T8 HO and Slimline Lamps

SKU No. of Lamps Per Circuit Footage Combined Total Footage Input Voltage Max Input Amps Max Input Watts Open Circuit Voltage
RSS296AT-120-277V 1-2 4′-12′ 4′-12′ 120-277V 1.40-0.64 166-162 950
RSS496AT-120-277V 2-4 4′-12′ 8′-24′ 120-277V 2.85-1.38 330-324 950
RSS696AT-120-277V 4-6 9′-18′ 18′-36′ 120-277V 3.82-186 454-450 950

208-347 Volt Applications

For use with T12 HO and Slimline Lamps

SKU No. of Lamps Per Circuit Footage Combined Total Footage Input Voltage Max Input Amps Max Input Watts Open Circuit Voltage
RSS296AT-208-347V 1-2 4′-16′ 4′-16′ 208-277-347V 0.76/0.60/0.46 147/147/148 950
RSS496AT-208-347V 2-4 4′-16′ 8′-32′ 208-277-347V 1.54/1.22/0.91 298/196/294 950
RSS696AT-208-347V 4-6 12′-24′ 24′-48′ 208-277-347V 2.40/1.80/1.40 464/464/452 950
RSS1648-26L-208-347V 2-6 8′-24′ 16′-48′ 208-277-347V 2.40/1.90/1.40 464/460/452 950

For use with T8 HO and Slimline Lamps

SKU No. of Lamps Per Circuit Footage Combined Total Footage Input Voltage Max Input Amps Max Input Watts Open Circuit Voltage
RSS296AT-208-347V 1-2 4′-12′ 4′-12′ 208-277-347V 0.69/0.55/0.41 133/133/132 950
RSS496AT-208-347V 2-4 4′-12′ 8′-24′ 208-277-347V 1.23/1.00/0.73 238/238/236 950
RSS696AT-208-347V 4-6 9′-18′ 18′-36′ 208-277-347V 2.35/1.75/1.35 455/451/436 950
RSS1648-26L-208-347V 2-6 8′-18′ 16′-36′ 208-277-347V 2.34/1.86/1.37 462/458/452 950

EESB Fluorescent Ballasts

  • For use with T12 HO, T8 HO and Slimline Lamps
  • Easy installations with easy to use red/blue parallel wiring
  • Rewiring of the lamp sockets required when used as a replacement for ferromagnetic ballasts
  • 5 Models replace 26 magnetic ballasts for less inventory requirements
  • Available in 120V and multi-voltage 120-277V
  • Runs cooler than conventional magnetic ballasts adding life to ballasts and lamps
  • Each lamp is on its own circuit and will stay powered if other lamps go out
  • Operates at a low line voltage so brown outs don’t effect it
  • Minimum starting temp: -30C
  • Light weight – from 2 to 9.5lbs
  • Title 24 Compliant

120 Volt Applications

For use with T12 HO, T8 HO and Slimline Lamps

SKU No. of Lamps Per Circuit Footage Input Voltage Max Input Amps Max Input Watts Open Circuit Voltage
EESB-1808-1L 1 18″-8′ 120V 0.85 100 800
EESB-424-13L 1-3 4′-24′ 120V 1.50 180 750
EESB-832-16L 1-6 8′-32′ 120V 2.40 282 800
EESB-1040-14L 1-4 10′-40′ 120V 2.70 328 850
EESB-1048-26L 2-6 10′-48′ 120V 3.00 355 800

120-277 Volt Applications

For use with T12 HO, T8 HO and Slimline Lamps

SKU No. of Lamps Per Circuit Footage Input Voltage Max Input Amps Max Input Watts Open Circuit Voltage
EESB-0216-12L 120-277V 1-2 2′-16′ 120V/208V/240V/277V 1.20/0.64/0.58/0.55 134/133/135/136 980
EESB-0432-14L 120-277V 1-4 4′-32′ 120V/208V/240V/277V 2.35/1.30/1.18/1.10 271/270/271/272 980
EESB-0250-16L 120-277V 1-6 2′-50′ 120V/208V/240V/277V 3.54/1.96/1.67/1.48 410/404/402/402 980
EESB-1048-26L 120-277V 2-6 10′-48′ 120V/208V/240V/277V 3.10/1.76/1.54/1.32 362/361/361/360 980

208-347 Volt Applications

For use with T12 HO, T8 HO and Slimline Lamps

SKU No. of Lamps Per Circuit Footage Input Voltage Max Input Amps Max Input Watts Open Circuit Voltage
EESB-424-13MV 1-3 4′-24′ 208V/240V/277V/347V 0.95/0.81/0.70/0.58 194/190/190/189 700
EESB-832-16MV 1-6 8′-32′ 208V/240V/277V/347V 1.38/1.22/1.05/0.84 287/286/283/280 800
EESB-1040-14MV 1-4 10′-40′ 208V/240V/277V/347V 1.58/1.34/1.14/0.93 320/318/314/310 900
EESB-1048-26MV 2-6 10′-48′ 208V/240V/277V/347V 1.85/1.60/1.50/1.10 380/377/374/370 800

Fluorescent HO Lamp Holders

  • 12″ lead length
  • Thermoplastic flexible sealing material expands/contracts with temperature changes
  • Electrical connection protected from moisture
  • Self extinguishing sealer adhesive
  • Will not crack or deteriorate like clay-based sealers
  • Electrical contacts remain rigid when expanded
  • Electrical contact with lamp remains strong even after hundreds of power cycles
  • Complies with UL 48 and UL 879
  • Available in Tombstone and Flush Mount versions
  • Rating: 660W, 600V / 1000V
  • Materials: GE® resins, Ni plated steels, stainless steels, “O” ring, and tin bronze contacts were used in the manufacturing of Allanson lamp holders. The 12” lead assemblies are stranded 18AWG tinned copper and have 1015/1032 UL ratings 221°F (105°C) and 1000V.
  • Mounting: High strength metal retaining clips ensure solid hold when installed per specifications

Lamp Holder Models

SKU Mounting Connection
1620 Tombstone Socket Spring
1621 Tombstone Socket No Spring
1622 Flush Socket Spring
1623 Flush Socket No Spring